40 years old female with prosthesis aortic valve had developed shortness of breath and consulted to our clinic on the first postpartum day. Her dyspnea was worsened at the last week. She had a history of Bentall operation before 16 years ago, and had a bi-leaflet mechanical prosthetic valve. After detection of pregnancy, her warfarin treatment had switched to enoxaparine 6000 IU subcutaneously for twice a day, continued throughout the pregnancy. Her weight was 62 kg. She did not have any blood test for factor Xa. On physical examination, she has orthopnea, tachypnea (24/min), tachycardia (128 bpm) and hypotension (85/55 mmHg). Electrocardiogram was uneventful with sinus tachycardia of 128 bpm with normal axis. Echocardiography revealed normal left ventricle size with left ventricle hypertrophy, ejection fraction of 60%, reduced motion of prosthetic-valve leaflets and an obstructing mass between the struts. Doppler ultrasonography showed that prosthetic aortic valve has a pressure gradient of 104/59 mmHg. These findings were consistent with prosthetic thrombosis. Moderate aortic regurgitation into the left ventricle was also detected. Transesophageal echocardiography showed 1.4 × 2.3 cm thrombotic material located over leaflets and adjacent to the posterior aortic wall. It was restricting the valve motion. The patient underwent emergency operation immediately. The thrombotic material over mechanical valve was extracted and there was no pathology seen on mechanical valve, graft repaired primarily. Postoperative recovery was fine. No bacteria were detected both direct microscopy and culture.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed245    
    Printed31    
    Emailed0    
    PDF Downloaded43    
    Comments [Add]    

Recommend this journal